Programming, 9. lockout – GE Industrial Solutions ASTAT-IBP Plus User Manual

Page 23

Advertising
background image

K

Std

300%

165

6

10

15

4

30

2

30

2

Hvy

450%

248

1

45

8

8

20

3

30

2

L

Std

300%

204

1

45

8

5

20

3

30

2

Hvy

450%

306

8

7

12

5

Y

Std

300%

240

1

45

8

7

20

3

30

2

Hvy

450%

360

1

M

Std

300%

315

6

10

12

5

28

3

30

2

Hvy

450%

473

2

30

8

8

15

4

30

2

Z

Std

300%

390

4

15

10

6

20

3

30

2

Hvy

450%

585

1

45

6

10

10

6

30

2

N

Std

300%

468

2

30

8

8

15

4

30

2

Hvy

450%

702

4

15

10

6

20

3

P

Std

300%

576

6

10

14

4

30

2

30

2

Hvy

450%

864

2

30

4

15

10

6

20

3

Q

Std

300%

744

4

15

9

6

24

3

30

2

Hvy

450%

1116

6

10

12

5

R

Std

300%

906

2

30

4

15

10

6

25

3

Hvy

450%

1359

6

10

S

Std

300%

1083

1

45

3

20

6

7

12

5

Max

1161

1

45

3

20

8

7

12

5

4-9. Lockout

4. Programming

4-10

The number of starts per hour that the ASTAT-IBP Plus can initiate is limited and depends on the starting current and the ramp time, as
listed below. The ASTAT-IBP Plus has a lockout feature that is designed to protect the SCRs between starts. This parameter should be
set before operating the ASTAT-IBP Plus. The lockout setting range is 0-45 minutes between starts. After starting a motor, the ASTAT-
IBP Plus goes into lockout mode for the period set for the LKXX parameter. If a consecutive soft start is attempted within the time set for
the LKXX parameter, error code E027 will appear on the display. See Table 7 for the appropriate value to program this parameter.

Note:

If soft stop is enabled, the lockout times listed should be increased by 50%.

Note:

Si l’arrêt progressif (Soft Stop) a été choisi, les temps de verrouiller hors devraient être augmentés de 50%.

Starting

Power

% of

Unit

Duty

Frame

Size

Cycle

Rating

Amps

NOTE: If control power is lost, lockout time resets to five minutes.

ATTENTION: Si la puissance de contrôle est perdue, le temps du relais de verrouillage se réarmeá cinq-minutes.

30 sec. start

LK time

Starts

between

per

starts,

hour

min.

20 sec. start

LK time

Starts

between

per

starts,

hour

min.

10 sec. start

LK time

Starts

between

per

starts,

hour

min.

5 sec. start

LK time

Starts

between

per

starts,

hour

min.