PAGE 16 13 APR 2000 MAN0373-01
CH. 3

Table 3.1 – Parameter Settings

Option

Card

Parameter

Description

Valid Input

Values

Default Value (o31 = 255)

o44

User Defined Broadcast Data 11

1-254

0;255*

255

o45

User Defined Broadcast Data 12

1-254

0;255*

255

o46

User Defined Control Data 1

1-254

0;255*

S06 Operation Command

o47

User Defined Control Data 2

1-254

0;255*

S01 Frequency Cmd

o48

User Defined Control Data 3

1-254

0;255*

S07 Universal Do

o49

User Defined Control Data 4

1-254

0;255*

S12 Universal Ao

o50

User Defined Control Data 5

1-254

0;255*

255

o51

User Defined Control Data 6

1-254

0;255*

255

o52

User Defined Control Data 7

1-254

0;255*

255

o53

User Defined Control Data 8

1-254

0;255*

255

o54

User Defined Control Data 9

1-254

0;255*

255

o55

User Defined Control Data 10

1-254

0;255*

255

Note: If the Option Card detects and invalid parameter value then the parameter number containing
the invalid value appears at o31 (Bus address). It is recommended that parameter o31 be checked
after the configuration is completed to make sure that all parameter values are valid.

* 0 and 255 are used to notate unused configuration parameter.

3.2.1

User Defined Parameters

The object of the user defined configuration parameters is to create a selectable data map for the Genius
data. There are 254 available parameters and only 12 broadcast and 10 control data words available on
the Genius network. The selectable map allows the user to configure what parameters and how many
are to be used.