GE Industrial Solutions HE300GEN150 User Manual
Page 35
PAGE 36 13 APR 2000 MAN0373-01
CH. 5
Data format [17]: Type code
Type
Generation
Series
Voltage series
Code
Type
Generation
Series
Voltage series
1
VG
G11/P11
For domestic
100V single phase
2
G
-
For Asia
200V single phase
3
P
-
For China
200V three phase
4
E
-
For Europe
400V three phase
5
C
-
For USA
575V three phase
6
S
-
-
-
Data format [18]: Code setting
Data 4
Data 3
Data 2
Data 1
Example) If o22 (Ai function selection)=123
Since 123=0123
H
Data format [19]: Amperage value Decimal data (positive):
Min. unit 0.01 for inverter capacity is not more than 30HP
Min. unit 0.01 for not less than 40HP respectively
Example) If F11 (electronics thermal overload relay 1 level)107.0A (40HP)
Since 107.0
×
10=1070=042E
H
If F11 (electronics thermal overload relay 1 level)=3.60A (1HP)
Since 3.60
×
100=360=0168
H
Data format [20] Transmission error code
Code
Description
Code
Description
1
FC (function code) error
71
CRC error
(no response)
2
Illegal address
72
Parity error
(no response)
3
Illegal data (Data range error)
7
NAK
- Priority for link
- No right for writing error
- Forbidden writing error
73
Other errors
(no response)
- Framing error
- Overrun error
- Bufferfull error
Example) If illegal address
Since 2=0002