Maintenance

Valve and pump inspection

Periodically inspect the valve or pump for signs of leakage or corrosion.

WARNING:
Risk for property damage, serious personal injury or death. You must replace
the valve or pump if corrosion or leakage is found.

Pairing after pump or valve replacement

If either the pump or the valve is replaced, device pairing is required. To pair

the devices, follow this procedure:
1.

Power up the valve by inserting the batteries.
If the valve is already in operation, remove and reinsert the batteries. If the
valve is being replaced, remove the batteries from the old valve before
pairing the new replacement with the pump. It is recommended to use a
fresh set of batteries in the new valve being installed.
a)

If a push-button / signal repeater device requires pairing, plug it
directly into the desired outlet.

2.

Open the timer cover on the pump. Slide the switch from the “ON” position
to the “OFF” position.

3.

Wait two (2) seconds and slide the switch from the “OFF” position to the
“ON” position.

4.

Wait two (2) seconds and slide the switch to the “OFF” position.

5.

Wait two (2) seconds and return the switch to the “ON” position.

When the device is successfully paired, the LED in the thermostat knob is lit. The

pump is now ready for service.

Replace the batteries

The system is designed to provide effective communication between the pump
and valve for approximately two (2) years after system start-up or battery
replacement when using two (2) 1.5 V LR06 alkaline batteries. When using
rechargeable batteries, it is recommended that they have a minimum 2500 mAh
capacity.
Do not mix new and old batteries or other makes of batteries, such as alkaline
with lithium-ion. The different attributes can negatively affect the system
performance or cause the batteries to leak fluid, overheat, or explode.
When new batteries are inserted into the valve, the valve will resume
communication with the pump.

CAUTION:
Risk of property damage or personal injury. You must replace the valve if battery
leakage is found.