WARNING:
Do NOT exceed the maximum working pressure of the pump. This information

is listed on the nameplate of the pump.

WARNING:
California Proposition 65 warning! This product contains chemicals known to

the state of California to cause cancer and birth defects or other reproductive

harm.

How the system works

The ecocirc

®

wireless potable hot water recirculation kit features a factory

paired pump and mixing valve that wirelessly communicate temperature data

and operational status between each other. The ecocirc

®

wireless pump with

built-in timer is installed on the supply side of the hot water source, as

presented below. The paired mixing valve is installed under the sink farthest

from the hot water source. A temperature sensor within the valve detects the

water temperature and wirelessly transmits this data to the pump.
The desired water temperature at the mixing valve is set remotely with the

thermostat dial on the pump. When the water temperature sensed at the valve

is below the desired setting, a signal is sent to the ecocirc

®

wireless pump to

begin circulating hot water throughout the system. The mixing feature of the

valve tempers the cold water at the faucet or tap, providing instant hot water at

this location and so satisfying the need for hot water at all upstream water

outlets. When the temperature requirement at the valve has been satisfied, a

signal is sent to turn off the pump. This system prevents continuous running and

saves energy.
For more energy savings, the ecocirc

®

wireless pump can be set for Timer

Operation to run only during the time periods when hot water is most frequently

required.
An optional push-button / signal repeater device is available to provide instant

hot water with a touch of a button. Pressing the push-button will activate the

pump and begin circulating hot water throughout the system, outside of the set

Timer Operation, until the desired temperature is met at the valve. Acting in its

secondary function as a signal repeater, this device will also extend the

operational range of the pump and valve and aid in the transmission of data

between the two devices where necessary.
The instant hot water delivery with the ecocirc

®

wireless potable hot water

recirculation kit saves water and time, while improving comfort, as water does

not need to run continuously while waiting for it to warm up.

Product Description

Bell & Gossett ecocirc

®

wireless Potable Hot Water Recirculation Kit Instruction

Manual

7