Symptom

Cause

Remedy

Pump is noisy

Air in the system

Turn off the ecocirc pump. Turn

on the hot and cold faucets/taps

until all air is purged from the

system.

Foreign matter in the rotor cavity Unplug pump and shut off water

supply. Open faucets/taps and

drain water from the piping.

Loosen the screw ring to separate

motor from the pump housing

and check for foreign matter.

Rotor does not seat properly.

Ensure the rotor is properly set

on the motor bearing by pushing

down on the rotor.

Water hammer that results from

the closure of the built-in check

valve.

Install water hammer arresters on

the hot and cold lines.

Hot water is not instantly

available at all faucets/taps

Faucets/taps are branched off

from the main hot water supply

line.

Hot water will take longer to

reach branched faucets/taps.

Water temperature at the valve is

at or above the set temperature.

Verify the temperature setting at

the pump.

Hot water source not producing

hot water.

Verify temperature setting at hot

water source.
Verify hot water source operation.

Distance between the pump and

valve is greater than 150 ft (45

m).

Install a signal repeater / push-

button to assist communication

between pump and valve.

Water at faucets/tap is too hot

The temperature setting on the

hot water source is too high.

Adjust temperature setting on

hot water source.

Troubleshooting