Specifications, Performance – John Wood Noritz N-069M-DV User Manual

Page 26

Advertising
background image

26

Item

Gas
Consumption

Maximum Hot Water Capacity

Capacity Range

Temperature Settings

Default Temperature Options

NG

LP

45

°

F Rise

6.9 Gal./min.

0.7-7.9 Gal./min.

100-150

°

F (In 5

°

F intervals),

160, 170, 176

°

F (In 10

°

F intervals) (14 Options)

120,130,140,176

°

F(Original is 120

°

F)

Maximum Performance

194,000 btuh

194,000 btuh

Minimum Performance

25,000 btuh

25,000 btuh

Specification

N-069M-DV

Indoor Wall Hanging

Direct Vent/Sealed Combustion

15-150 PSI

0.7 GPM

24.2"(Height) x 18.3"(Width) x 9.4"(Depth)

63 lbs.

0.3 Gallon

3/4"

3/4"

3/4"

120 VAC (60Hz)

NG:70W, LP:74W, Freeze Prevention 135W

Zincified Steel Plate/Polyester Coating

Stainless Steel

Copper Sheeting, Copper Tubing

Flame Rod, Thermal Fuse, Pressure Relief Valve,

Lightning Protection Device (ZNR),

Electric Leakage Prevention Device (GFCI), Overheat

Prevention Device, Freezing Prevention Device,

Fan Rotation Detector

Remote Controller, Remote Controller Cord,
Anchoring Screws

Specifications

Specifications

• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water

pressure, water supply, piping conditions, and water temperature.

Performance

Item

Model Name

Type

Ignition

Operating Pressure

Minimum Flow Rate

Dimensions

Weight

Water Holding Capacity

Accessories

Installation
Air Supply/Exhaust

Connection Sizes

Power Supply

Materials

Water Inlet

Hot Water Outlet

Gas Inlet

Supply

Consumption

Casing

Flue Collar

Heat Exchanger

Safety Devices

Direct Ignition

SAR8192-2_014_026_E_J.p65

05.11.29, 9:01 PM

Page 26

Adobe PageMaker 6.5J/PPC

Advertising