Quick connect, Plumbing/general, Quick connect multi system installation – John Wood Noritz N-069M-DV User Manual

Page 37: Typical plumbing, System diagram

Advertising
background image

37

3.

Quick Connect Multi System Installation

• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick

Connect Cord.

Typical Plumbing

The Quick Connect Cord is 6 ft. long. Install the two units 18.5"-37.4" apart at the center to
ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units.)

* When connecting 2 devices, use only a

single remote controller.

Note: Connect the remote

controller to only one
of the devices.

System Diagram

• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold

water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold
temperatures.

G

Quick Connect
Cord

Remote Controller Cord

Gas Supply Piping

Cold Water Supply

Hot Water

Remote Controller

Terminal Block

Cord
Connector

Cord
Connector

Leave enough clearance around the plumbing
to apply insulation. It will be necessary to add
bends to the piping to ensure that this
clearance is available.

Size the piping to allow for the maximum
flow rates of the units.

Union

Distance at center: 18.5-37.4".

Quick Connect
Cord

Pressure
Relief
Valve

Union

Gas Valve

Union

Shutoff
Valve

Shutoff Valve

Hot Water

Shutoff
Valve

Cold Water

Distance on sides

0.19-19".

Make this distance as short as possible.
* The hot water temperature will
become unstable as the pipe
length increases.