Installation

Check

4. Drill holes for the remaining four screws.

5. Hang the unit again by the first screw, and then

insert and tighten the remaining four screws.

6. Take waterproofing measures so that water does

not enter the building from screws mounting the
device.

• Make sure the unit is installed securely so that it will

not fall or move due to vibrations or earth-quakes.

Securing to the wall

Mounting Bracket
(upper)

Tapping Screw

Location of Screw Hole

1. Drill a single screw hole, making sure to hit a stud.

2. Insert and tighten the screw and hang the unit by

the upper wall mounting bracket.

3. Determine the positions for the remaining four screws

(two for the top bracket and two for the bottom), and
remove the unit.

• The weight of the device will be applied to the wall. If the strength of the wall is not suffi-
cient, reinforcement must be done to prevent the transfer of vibration.
• Do not drop or apply unnecessary force to the device when installing. Internal parts may

be damaged and may become highly dangerous.

• Install the unit on a vertical wall and ensure that it is level.

Locating Screw Holes

Locating Screw Holes

Mounting

Structure

Caution

• When installing with bare hands,

take caution to not inflict injury.

• Be careful not to hit electrical

wiring, gas, or water piping while
drilling holes.

Item

8.

Vent Pipe Installation

(Indoor Installation Only)

Vent Terminal Installation

• Follow the installation instructions included with the vent terminal and which are reproduced at the end

of this manual.This appliance must be vented through the wall,not vertically to the roof.