John Wood Noritz N-069M-DV User Manual

Page 64

Advertising
background image

64

3) Adjusting the vent terminal length

Make sure the vent terminal has been set to the appropriate length and the outlet is oriented
properly to prevent combustion and operation problems.

The length of the vent terminal must be
adjusted to fit with the wall thickness before
the installation is completed.

The sleeve length can be
adjusted in increments
of 0.4".

<Screw positions>
The following figure shows the points to screw the
cylinder to for the different installation orientations.

Screwing position for
installation pattern (3)

4) Attach vent terminal to the wall flange.

* Installation pattern (3) yields a clearance between the vent terminal and
the wall surface. Fill this clearance with a high temperature sealant.

Wall flange

Vent terminal

Wing nut

The following figure shows installation pattern (1).

External wall surface

Standard projection
length: 3"

The red line should be visible.
The red rectangle should not be
visible from the outdoors.

Screwing position for
installation pattern (2)

Fill in clearance with
sealant

Note: If the vent terminal will be installed in

orientations (2) or (3) from the table on the
previous page, the outlet cylinder will have
to be rotated so that it is oriented properly.

Installation pattern (1),
as is with shipment

Wind packing along the red
rectangle only for wall
thicknesses of 14.5" to 27".

Remove this screw and slide
out the external cylinder.

SAR8192-2_060_067_E_J.p65

05.11.29, 9:01 PM

Page 64

Adobe PageMaker 6.5J/PPC

Advertising