Command and Response table for basic SIS commands (continued)

Command

ASCII command

(host to device)

Response

(device to host)

Additional description

Presets, I/O Names

Write preset name

EX1)

,

X1!

NG

}

Nmg

X1)

,

X1!]

Example:

E

1,Security1NG

}

Nmg

01

,Security1

]

Name preset 1 “Security 1”

Read preset name

EX1)

NG

}

X1!]

Example:

E

2NG

}

Security2

]

Recall a preset

X1)

.

Rpr

X1)]

Command character is a
period

.

Example

5

.

Rpr

X1)]

Recall preset 5, which
becomes the current
configuration.

Write input name

EX#

,

X1!

NI

}

Nmi

X#

,

X1!]

Example:

E

9,Podium cam1NI

}

Nmi

0

9,Podium cam1

]

Name input 9 “Podium cam1”

Read input name

EX#

NI

}

X1!]

Write output name

EX@

,

X1!

NO

}

Nmo

X@

,

X1!]

Example:

E

1,Main PJ1NO

}

Nmo

0

1,Main PJ1

]

Name output 1 “Main PJ1”

Read output name

EX@

NO

}

X1!]

Resets

Reset presets and names

E

ZG

}

Zpg

]

Clear all presets and their
names.

Reset an individual preset

EX1)

ZG

}

Zpg

X1)]

Clear preset

X1)

.

Reset a group

E

Z

X2)

GRPM

}

GrpmZ

X2)]

Delete all members from
group

X2)

, reset parameters

and soft limits.

NOTE: See

Group Masters

on page 69, for more information about audio group masters.

Reset flash

E

ZFFF

}

Zpf

]

Reset flash memory
(erase user-supplied files).

System Reset (factory
defaults)

E

ZXXX

}

Zpx

]

Resets all processors, level
controls and mixers to default.

Reset all device settings
and delete files

E

ZY

}

Zpy

]

NOTE: This reset excludes IP settings such as IP address, subnet mask, gateway IP address, unit name, DHCP setting and

port mapping (telnet/web/direct access) in order to preserve communication with the device.
This reset is recommended after a firmware update.

Absolute reset

E

ZQQQ

}

Zpq

]

Similar to

System Reset,

plus sets the IP address
to

192.168.254.254

and the subnet mask to

255.255.0.0

.

NOTES:

X#

= Input number

01 – 06

X@

= Output number

01 – 04

X1)

= Preset #

32 maximum (

0

= current configuration)

X1!

= Name

12 characters maximum

X2)

= Group master group number

01 – 32