FBS Fixed Filters

Fixed filters are notch filters with an adjustable center frequency and Q, and up to 30 dB
of cut. The fixed filters are typically set by converting dynamic filters to fixed, however
adjustments to filter parameters can be made manually from the

Fixed Filters

tab.

Fixed Filters are inactive and the filter type is set to Unused by default.

Figure 35.

FBS Fixed Filters Tab

No filter parameters are displayed when the filter type is set to Unused. As a filter is

moved to the fixed filter tab from a dynamic filter, the filter becomes active and displays

Notch

as the filter type. The parameters copied from the dynamic filter are displayed in

the same line. Once a fixed filter is active, settings can be modified or adjusted if needed.
Fixed filters can also be individually bypassed by clicking the

Bypass

button.

FBS Settings Ranges and Fixed Filter Defaults

FBS Parameter

Settings Range

Default Setting

Frequency

20 Hz to 20 kHz

N/A

Q

5.000 to 65.000

30.000

Attack Time

0.0 ms to 1000.0 ms

10.0 ms

Filter Hold Time

0 seconds to 9 hours

00:00:00; Disabled

Fixed Filter Parameter Settings Range

Default Setting

Frequency

20 Hz to 20 kHz

1000.0 Hz

Q

1.000 to 65.000

30.000

Cut

Up to 30 dB cut

0.0 dB

DMP 64 • Software Control

44

Advertising