FBS Settings

The

Settings

tab enables selection of the feedback suppressor parameters.

For Composite View show: — The graph view is set by one of three buttons:

Only Dynamic FBS Filters

Only Fixed FBS Filters

Dynamic & Fixed FBS Filters

(default)

Mode: Q — Adjusts the notch filter Q used by dynamic filters. Similar to the
parametric filter Q, it changes the bandwidth of the filter. The default setting can be
modified in

Tools>Options

. The range is from 5 to 65. Larger values provide less

change to the audio frequency response while lower values can provide greater
feedback suppression but with more impact to the tonal response of the source
audio.
Suggested values for specific applications are:

Q Value

Application

7

Voice with considerable feedback potential

30

Voice with less feedback potential

65

Music with minimal feedback potential

Attack Time — Sets the time at which dynamic filters are generated after feedback
detection. A longer attack time (greater than 200 ms) reduces the chance that music
or audio content will trigger the dynamic filters to respond. A shorter attack time (less
than 2 ms) reduces the time between when feedback is detected and suppressed.

Hold Time — Expressed in

hours:minutes:seconds

up to 9 hours. Hold time sets

the time a dynamic filter setting persists before the filter is cleared. When hold time is
disabled, dynamic filters persist indefinitely unless cleared manually or the device is
power cycled.
Hold time reverts to 00:00:00 when disabled (