FBS Dynamic Filters

This tab contains the fifteen dynamic filters, with a scroll bar to display filters hidden due to
dialog box size.
Dynamic filters are notch filters that are cut only, providing attenuation up to 30 dB at the
specified Q. The default Q is set in the

Tools>Options

menu, but can be changed on

the settings tab prior to engaging the FBS dynamic filters. Changing the Q setting after
dynamic filters have been generated clears all dynamic filters.

Figure 34.

FBS Dynamic Filters Tab

Frequency and cut values are read only. Dynamic filters are in auto-detect mode when the
FBS block is active (when

Bypass FBS

is off). If testing reaches a point where no further

changes are desired, the lock button can be engaged. The lock mode of operation is
temporary, and is intended to be used during setup of the FBS. When the FBS dialog box
is closed, lock mode is automatically disengaged.
If there are specific dynamic filters the user wants to assure are not overwritten, press the

Move to Fixed

button to write the designated filter settings to the first available filter in the

Fixed Filter tab.

NOTE: When a dynamic filter setting is moved to the fixed filter, it automatically

clears that frequency from the dynamic filter.

The

Clear

button removes a detected frequency from the corresponding dynamic filter. A

cleared filter reverts to auto-detect mode unless

Lock

mode is engaged.