Connectors and Settings

REMOTE

1

2

3

4

5

6

INPUT

PRE-PEAK

ON

OFF

OUTPUT

MONO AUDIO OUTPUT

L

R

POWER

12V

0.5A MAX

MTP SW6

RS-232

INSERT

Tx Rx

SPARE

1

3

7

4

6

5

2

Figure 6.

MTP SW 6 rear panel features

a

DC power connector — Plug the external 12 VDC power supply into this 2-pole

captive screw connector. See

Power supply wiring

to wire the connectors.

NOTE: The remote power capabilities available with certain MTP models are not

supported by this unit; the transmitter, switcher, and receiver must all be
powered.

b

Input connectors — Connect up to six TP cables from transmitters to these RJ-45

female connectors. See

TP cable termination

to wire the RJ-45 connectors.

CAUTION: Do not connect this device to a computer data or telecommunications

network.

NOTES: • See

Table 1

for recommended transmission ranges.

• You must configure the switcher for the appropriate content on the

audio/RS-232 wire pair (pins 3 and 6) for each TP input. See the

Audio/RS-232 TP input (wire pair 3 and 6) configuration

SIS commands.

• For best results, use a combined cable length of at least 50 feet (15 m)

between the transmitter and the receiver on the MTP SW6 output.

• RJ-45 termination with CAT 5, CAT 5e, or CAT 6 cable must comply

with the TIA/EIA T568A or TIA/EIA T568B wiring standards for all
connections.

• RJ-45 termination with Enhanced Skew-Free A/V UTP cable must

comply with TIA/EIA T568A only.

• When low resolution MTPs (S-video and composite video) are the

TP inputs, the MTP SW6 audio circuits are compatible only with
the newer generation, mono audio models. See the appropriate
MTP transmitter/receiver user’s manual to determine which MTP models
you have.

c

Output connector — Connect one end of a terminated TP cable to this RJ-45 female

connector.

Connect the free end of the same TP cable from the switcher to the RJ-45 female
connector on a compatible MTP receiver.

See

TP Cable Termination

to properly wire the RJ-45 connectors.

MTP SW6 • Installation and Operation