Unit-initiated messages, Error responses, Unit-initiated messages error responses – Extron Electronics MTP SW6 User Guide User Manual

Page 25: Oughout the, Unit-initiated, Messages

Advertising
background image

Unit-Initiated Messages

When a local event, such as a front panel operation, auto switch, or error condition,
occurs, the unit responds by sending a message to the host. The unit-initiated messages
are listed below:

(c)COPYRIGHT 2008, EXTRON ELECTRONICS “MTP SW6”,

v.vv

]]

The connected unit issues the appropriate copyright message (above) when it first powers
on.

v.vv

is the firmware version number.

ALL

X!

]

The unit sends the All message as a unit-initiated message under two conditions:

You press a front panel input button.

An input selection occurs via auto switch mode.

NOTE: The switcher returns the All message for every press of an input button, even if

no switch occurs. No switch will occur if you press an already selected button
or if the switcher is in auto switch mode (front panel input selection is disabled).

F

X1$

]

The unit sends the F message whenever the switch mode is changed from the front panel.

ILVL

X!

*

X@

]

The unit sends the Ilvl message whenever the level adjustment is changed from the front
panel.

IPEK

X!

*

X#

]

The unit sends the Ipek message whenever the peaking adjustment is changed from the
front panel.

ISEQ

X!

*

X%

*

X%

*

X%

]

The unit sends the Iseq message whenever the skew settings have been changed from the
front panel. The

X%

values are the red, green, and blue skew values, in that order.

ZPK]

The unit sends the Zpk message whenever the skew settings have been reset from the
front panel.

Error Responses

When the unit receives a valid SIS command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command because the
command is invalid or it contains invalid parameters, the unit returns an error response to
the host. The error response codes are:

E10

-

Invalid command

E11

-

Invalid preset number

E13

-

Invalid parameter

E14

-

Invalid command for this configuration

MTP SW6 • Remote Control

21