Remote RS-232/contact closure connector —

Connect a computer or control

system to this 9-pin D connector (figure 9) to allow remote control using the Simple
Instruction Set (SIS

), the Extron graphical control program for Windows, or a contact

closure device. See

Remote Control

for details.

REMOTE

PIN RS-232

Contact

Closure Function

1

In #1

Input #1

Input #2

Input #3
Input #4
Input #5
Input #6

2

TX

Transmit data

3

RX

Receive data

4

In #2

5

Gnd

Gnd

Ground

6

In #3

7

In #4

8

In #5

9

In #6

Figure 9.

Remote connector pinout

You can also connect a KP 6 remote control keypad (part #60-111-20) or an IR 102 Kit
infrared remote control (part #70-224-01) system to this connector.

NOTE: The switcher can be controlled only by an RS-232 device OR a contact

closure device, not both.

NOTE: The cable used to connect the Remote port to a computer, control, contact

closure device, or IR control kit may need to be modified by removing pins
or cutting wires. If unneeded pins are connected, the switcher may hang
up. See

Remote Control

for additional information.