Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

Local audio output volume

Set the local audio output
volume to a specific value

X1@

V

Vol

X1@]

Example:

50V

Vol50

]

Set the output volume to 50%.

Increment volume

+V

Vol

X1@]

Increment volume by 1%.

Example:

+V

Vol51

]

Decrement volume

-V

Vol

X1@]

Decrement volume by 1%

Read output volume

V

X1@]

Audio or RS-232 mute commands

Audio or RS-232 mute

1Z

Amt1

]

Mute (silence) the audio or RS-232 output.

Audio or RS-232 unmute

0Z

Amt0

]

Unmute the audio or RS-232 output (audio on).

Read audio/RS-232 mute
status

Z

X1#]

1 = mute on, 0 = mute off.

Switch mode

Set normal (manual)
switch mode

1#

F1

]

The user selects an input manually, from the front
panel or under remote control.

Set auto switch mode

2#

F2

]

The switcher automatically switches to the highest
numbered input with signals present. Manual input
selection is disabled.

Front panel lock (executive mode)

Lock the front panel

1X

Exe1

]

Lock the front panel level, peaking, and skew
functions. The switch mode (auto or manual) cannot
be changed. Input selection is still available.

Unlock the front panel

0X

Exe0

]

All front panel functions are available.

View lock status

X

X1#]

Resets

Reset all video level and
peaking adjustments

E

ZT

}

Zpt

]

Clear all video level and peaking adjustments to their
default (0) values.

Reset all skew
adjustments

E

ZK

}

Zpk

]

Clear all input and output skew values to 0 ns.

Reset audio input levels

E

ZA

}

Zpa

]

Reset all audio input levels (gain and attenuation) to
0 dB.

Reset audio output levels

E

ZV

}

Zpv

]

Reset the audio output level (volume) to 100% (no
attenuation.

Reset whole switcher

E

ZXXX

}

Zpx

]

Reset all level and peaking, skew, audio input gain
and attenuation values to 0. Reset output volume to
100% ( no attenuation).

Information requests

Information request

I

V

X!

•A

X!

•F

X1$

•Vmt

X1#

•Amt

X1#

•Exe

X1#]

V (selected video input) • A (selected audio input) •
F (switch mode) • Vmt (video mute — not supported
by this switcher)
• Amt (audio mute status) • Exe
(front panel lock).

Request part number

N

68-928-01

]

Query controller version

Q

X1%]

Example:

Q

1.23

]

The factory-installed firmware version is 1.23 (sample
value only).

Request system threshold
status

42S

X@]

NOTE:

X!

= Input number

1-6

X@

= Threshold

0 = outside threshold 1 = within threshold

X1@

= Volume adjustment range

0 - 100

X1#

= Mute, front panel lock

0 = off

1 = on

X1$

= Switch mode

1 = normal (manual) 2 = auto

X1%

= Firmware version

v.vv

Command/response table for SIS commands (continued)

MTP SW6 • Remote Control

25

Advertising