Command/resp onse table for sis commands, Command/response table for sis commands, Input – Extron Electronics MTP SW6 User Guide User Manual

Page 27: Selection, Sis commands for details, Available as an sis command. see the, Auto level and peaking, Adjustment, Sis command, Section and the

Advertising
background image

Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

Input selection

NOTE:

The switcher supports 1-, 2-, or 3-digit numeric entries (1!, 02&, or 003%). The switcher reports all selections with 1-digit

numbers.

NOTE:

The & select and % select commands for video can be used interchangeably.

Select input

X!

video and

audio to output

X!

!

All

X!]

Select input

X!

video and audio to be the output.

Example:

1!

All1

]

Select input 1 video and audio.

Select input

X!

video

only to output

X!

&

Vid

X!]

Select

X!

video (audio is broken away).

Example
(see 2nd note above):

5&

Vid1

]

Select input 5 video.

Select input

X!

video

only to output

X!

%

Vid

X!]

Select

X!

video (audio is broken away).

Select input

X!

audio

only to output

X!

$

Aud

X!]

Select

X!

audio (audio is broken away).

Example:

2$

Aud2

]

Select input 2 audio.

Auto level and peaking adjustment

NOTE:

The switcher must be running firmware version 1.02 or newer (issue the Q SIS command). Older firmware versions appear to

respond correctly, but do not adjust the level and peaking values correctly.

Execute auto peaking
calibration
(with optional MTP signal
generator)

EX!AADJ}

AadjX!*2] {start}
AllX!] {switch}
AadjX!*X@] {finished}
IpekX!*X#] {new value}
IlvlX!*X$] {new value}

Switch input X! to the output and auto adjust the
peaking on input X!. The X@ value in the responses
reports whether the adjustment value was within or
outside of the threshold.

NOTE:

Before issuing the auto calibration command:

1. Disconnect the power and RJ-45 cables at the MTP transmitter connected to X!.
2. Connect the two cables to the optional MTP signal generator.
3. If the input cable is longer than 300 feet (90 m), set the MTP signal generator Pre-

Peak switch on (up when the RJ-45 connector on the signal generator is to the right
as shown). If the cable is shorter than 300 feet (90 m), set the switch down.

Pre-Peak
is on

Manual video peaking adjustment

Set a peaking value

EX!

*

X#

IPEK

}

Ipek

X!

*

X#]

Set the peaking to

X#

.

Increment peaking

EX!

+IPEK

}

Ipek

X!

*

X#]

Increase peaking setting 1 step.

Decrement peaking

EX!

-IPEK

}

Ipek

X!

*

X#]

Decrease peaking setting 1 step.

Show peaking

EX!

IPEK

}

X#]

Manual video level adjustment

Set a level value

EX!

*

X$

ILVL

}

Ilvl

X!

*

X$]

Set the level to

X$

.

Increment level

EX!

+ILVL

}

Ilvl

X!

*

X$]

Increase level setting 1 step.

Decrement level

EX!

-ILVL

}

Ilvl

X!

*

X$]

Decrease level setting 1 step.

Show level

EX!

ILVL

}

X$]

NOTE:

X!

= Input number

1-6

X@

= Threshold

0 = outside threshold

1 = within threshold

X#

= Input peaking range

00 - 65

X$

= Input level range

000 - 255

Command/Response Table for SIS Commands

MTP SW6 • Remote Control

23