Simple Instruction Set

Control

Host-to-Interface Communications

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
unit executes the command and sends a response to the host device. All responses from
the unit to the host end with a carriage return and a line feed (CR/LF = ]), which signals

the end of the response character string. A string is one or more characters.

Symbol Definitions

Symbols (variables), defined on the next page, are used throughout the

Unit-Initiated

Messages

section and the

Command/Response Table for SIS Commands

. The symbols

represent variables in the unit-initiated messages and the command/response table fields.

]

= CR/LF (carriage return/line feed)

}

= Carriage return (no line feed)

=

Space (hard) character

X!

= Input

1 – 6

X@

= Threshold

0 = outside of threshold range
1 = within threshold

X#

= Input peaking range

00 – 65

X$

= Input level range

00 – 255

X%

= Skew adjustment range

00 – 31 (each step = 2ns)

X^

= Video plane

0 = red
1 = green
2 = blue

X&

= RS-232 insert status

0 = disabled
1 = enabled

X*

= Audio/RS-232 wire pair input type

0 = audio
1 = RS-232

X(

= Audio gain

0 – 24 (1 dB/step)

X1)

= Numeric dB value

–18 to +24 (45 steps of gain or
attenuation) (Default = 0 dB)

X1!

= Audio attenuation

1 – 18 (1 dB/step)

X1@

= Volume adjustment range

0 – 100

X1#

= Mute, Front panel lock

0 = off
1 = on

X1$

= Switch mode

1 = normal (manual)
2 = auto

X1%

= Firmware version

v.vv

MTP SW6 • Remote Control