Extron Electronics PVS 405D User Guide User Manual

Page 29

Advertising
background image

Command

ASCII Command

(host to switcher)

Response

(switcher to host)

Additional Description

Input audio gain and attenuation

NOTE: The VoiceLift and Aux input audio are independent and not affected by the output volume.

Set specific input
gain/attenuation

X@

*X3%G

InX@•AudX3%]

Set gain/attenuation on specified input

X@

to

X3%

dB.

Increment specific
input gain

X@

+G

InX@•AudX3%]

Increment specific input

X@

audio level

(up).

Decrement specific
input gain

X@

-G

InX@•AudX3%]

Decrement sepcific input

X@

audio level

(down).

View specific input
gain

X@

G

X3%]

View specific input

X@

audio level.

Verbose response

InX@•AudX3%]

View current input
gain

G

X3%]

View current input audio level.

Verbose response

InX@•AudX3%]

Output volume

Set specific volume

X3#

V

VolX3#]

Set volume to

X3#

.

Increment

+V

VolX3#]

Increase volume.

Decrement

-V

VolX3#]

Decrease volume.

View volume

V

X3#]

View current volume setting.

Verbose response

VolX3#]

Front panel security lockout (Executive Mode)

Enable Executive

1X

Exe1

]

Lock entire front panel.

Disable Executive
mode

0X

Exe0

]

Unlock front panel controls. All front
panel adjustments can be made
(default).

View Executive
mode status

X

X3@]

View the current status:
0 = off [default], 1 = on

Verbose response

ExeX3@]

Pass-through mode (dedicated VoiceLift port)

Configure pass‑
through mode

E

1CD}

Cpn1]

Set VoiceLift port to pass‑through mode.

Terminate pass‑
through mode

E

0CD}

Cpn0]

Stop pass‑through mode (default).

View pass‑through
mode

E

CD}

X2&]

View pass‑through mode

Verbose response

CpnX2&]

NOTE:

X@

= Audio input number: 1 through 5, 7 (VoiceLift), 8 (Aux)

X2&

= Pass‑through mode:

0 = Not in pass‑through mode (default)

1 = In pass‑through mode


X3@

= On/Off: 0 = off/disable, 1 = on/enable

X3#

= Audio output volume: 000 to 100 (‑100dB to 0dB, in 1 dB steps), default 80

X3%

= Input audio gain and attenuation: ‑18 to +24 dB V, in 1 dB steps

Inputs 1‑5 and 8; default is 0 dB

Input 7 (VoiceLift); default is ‑3 dB

PVS 405D • SIS Communication and Control

23

Advertising