Projector, Ir control, Stp input cable – Extron Electronics PVS 405D User Guide User Manual
Page 56
PVS 405D • Connector Wiring
50
NOTE: Some projectors require NULL connection wiring, which inverts the Tx and Rx
connections. See the projector guide for details.
IR control for a connected input device such as a BluRay player can be made through the
PVT wallplate.
The connections between the MLC 104 IP Plus and the PVS 405D switcher should look
like the figure below.
L
R
DO NOT
GROUND
OR SHORT
SPEAKER
OUTPUTS
4/8
Ω
3A MAX
POWER
12V
HDMI
1/2
SIG
LINK
SIG
LINK
3/4
INPUTS
OUTPUT
AUDIO OUT
PVS 405SA IP
AMPLIFIED AUDIO OUT
PAGING
SENSOR
PVT IN
PVT IN
L
R
AUX
OVER PVT REMOTE
VOICELIFT
LAN 1
LAN 2
LAN 3
INPUT 5
+V
L
R
RS-232
Tx Rx
IR
S G
G
2
3
GR
O
UND
1
IR IN
GR
OUND
IR OU
T
CM
SC
P
GR
OUND
GR
OUND
Tx
Rx
DISPLAY
RS-232/IR
LAN
PRESS TAB WITH
TWEEKER TO REMOVE
A B
MLS PWR
RS-232 12V
DIGITAL
I/O
A B C D E
COMM LINK
+V OU
T
GR
O
UND
Tx
Rx
+12V IN
CONFIG
DISPLAY
VOLUME
MLC 104 IP PLUS
ON
VCR
DVD
PC
OFF
1
2
3
4
RS-232
MLC 104 IP Plus right side panel
MLS and Power ports
RS-232 12V
MLS PWR
A B
Rx
Tx
GROUND
GROUND
+12V IN
NOTES:
•
You must connect a
ground wire
between the MLC and PVS.
• If you use cable that has a drain
wire, tie the drain wire to ground at
both ends.
G
Ground
+12 VDC input
Ground (Gnd)
Transmit (Tx)
B
Receive (Rx)
A
Transmit (Tx)
Receive (Rx)
Tx
Rx
IR control
S
Ground
G
IR Out
Rx
Tx
Projector
GROUN
D
IR OU
T
Tx
Rx
DISPLAY
RS-232/IR
Ground
RS-232
To Supplied
PVS Switcher
Power Supply
(12 VDC, 4 A)
To Blu-ray (or similar) input device
Optional PVT Front Panel
IR Output Connection
VGA IN
AUDIO
IN
OUT
LOCAL OUT
AUDIO IN
HDMI IN
IR OUT
S
G
HDMI IN #1
RGB IN #2
IR Emitter
STP Input Cable
CLASS 2 WIRING
Figure 38.
MLC wiring to the PVS 405D Switcher