PVS 405D • Connector Wiring

50

NOTE: Some projectors require NULL connection wiring, which inverts the Tx and Rx

connections. See the projector guide for details.

IR control for a connected input device such as a BluRay player can be made through the
PVT wallplate.
The connections between the MLC 104 IP Plus and the PVS 405D switcher should look
like the figure below.

L

R

DO NOT

GROUND

OR SHORT

SPEAKER

OUTPUTS

4/8

Ω

3A MAX

POWER
12V

HDMI

1/2

SIG

LINK

SIG

LINK

3/4

INPUTS

OUTPUT

AUDIO OUT

PVS 405SA IP

AMPLIFIED AUDIO OUT

PAGING

SENSOR

PVT IN

PVT IN

L

R

AUX

OVER PVT REMOTE

VOICELIFT

LAN 1

LAN 2

LAN 3

INPUT 5

+V

L

R

RS-232

Tx Rx

IR

S G

G

2

3

GR

O

UND

1

IR IN

GR

OUND

IR OU

T

CM

SC

P

GR

OUND

GR

OUND

Tx

Rx

DISPLAY

RS-232/IR

LAN

PRESS TAB WITH

TWEEKER TO REMOVE

A B

MLS PWR

RS-232 12V

DIGITAL

I/O

A B C D E

COMM LINK

+V OU

T

GR

O

UND

Tx

Rx

+12V IN

CONFIG

DISPLAY

VOLUME

MLC 104 IP PLUS

ON

VCR

DVD

PC

OFF

1

2

3

4

RS-232

MLC 104 IP Plus right side panel
MLS and Power ports

RS-232 12V

MLS PWR

A B

Rx

Tx

GROUND

GROUND

+12V IN

NOTES:

You must connect a

ground wire

between the MLC and PVS.

• If you use cable that has a drain

wire, tie the drain wire to ground at
both ends.

G

Ground

+12 VDC input

Ground (Gnd)

Transmit (Tx)

B

Receive (Rx)

A

Transmit (Tx)

Receive (Rx)

Tx
Rx

IR control

S

Ground

G

IR Out

Rx

Tx

Projector

GROUN

D

IR OU

T

Tx

Rx

DISPLAY

RS-232/IR

Ground

RS-232

To Supplied

PVS Switcher

Power Supply

(12 VDC, 4 A)

To Blu-ray (or similar) input device

Optional PVT Front Panel

IR Output Connection

VGA IN

AUDIO

IN

OUT

LOCAL OUT

AUDIO IN

HDMI IN

IR OUT

S
G

HDMI IN #1

RGB IN #2

IR Emitter

STP Input Cable

CLASS 2 WIRING

Figure 38.

MLC wiring to the PVS 405D Switcher

Advertising