TPS150 Switching and Transmission System • Installation

2-8

TP Cable Termination

RJ-45 termination must comply with the TIA/EIA T 568A or TIA/EIA T 568B
wiring standards for all connections.

The TPS150 works with either shielded or unshielded cables. However, to
comply with FCC rules, shielded (STP or FTP) cables must be used.

Figure 2-8 details the recommended termination of CAT 5/5e/6 TP cable with RJ-45
connectors in accordance with the TIA/EIA T 568A or TIA/EIA T 568B wiring
standards. You can use either standard, but ensure that you use the same standard
on both ends of the cable.

5

Pin

1

2

3

6

7

8

4

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Wire color

568 A

568 B

White-orange

Orange

White-green

White-blue

Green

White-brown

Brown

Clip Down

Side

1

1&2

3&6 4&5

7&8

2 3 4 5 6 7 8

1

Pins

2 3 4 5 6 7 8

RJ-45

connector

Twisted

Pairs

Blue

Blue

5

Pin

1

2

3

6

7

8

4

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Wire color

568 A

568 B

White-orange

Orange

White-green

White-blue

Green

White-brown

Brown

Blue

Blue

Blue +/V. sync +

Blue –/V. sync –

RS-232 +

Green –/H. sync –

RS-232 –

Red –

Red +

RGB video

signals

Green +/H. sync +

RS-232 +

Y –

RS-232 –

C –

C +

S-video signals

Y +

B-Y +

B-Y –

RS-232 +

Y –

RS-232 –

R-Y –

R-Y +

Component video

signals

Y +

RS-232 +

Video –

RS-232 –

Composite video

signals

Video +

Figure 2-8 — TP cable termination