4-5

TPS150 Switching and Transmission System • Serial Communications

9

.

Click Inline Model > Query Hardware to configure the ICS100 program to
communicate with the TPT150 and to confirm that communications have been
established with the transmitter. The connected window appears (figure 4-5).

Figure 4-5 — Connected window

10

.

Click OK.

11

.

Use the software to configure serial port settings, program the input and
projector codes, and/or operate the transmission system. See the procedures
on the following pages.

After you are finished sending commands to the transmitter, always end the
session by selecting a different address from the one assigned to the TPT150.
This prevents the transmitter from responding to commands meant for another
unit.

12

.

Click Inline Model > Select Address. The Addresses window (figure 4-4)
appears.

13

.

Click and drag on the slider or click the scroll up ( ) or scroll down ( )
button until an address other than the transmitter’s address is visible.

14

.

Click on the desired address.

15

.

Click OK.