4-13

TPS150 Switching and Transmission System • Serial Communications

X2

=

Input number

01 – 04

X3

=

On/off status

0 = off, 1 = on

X4

=

Input volume

–15 (dB) of attenuation (minimum volume) through 00 (dB) (maximum volume)

X5

=

Output level

–31 (dB) of attenuation (maximum attenuation) through 20 (dB) (maximum gain)

X6

=

Button or code

01 = input 1 code

04 = input 4

02 = input 2 code

05 = projector power off code

03 = input 3 code

06 = projector power on code

X7

=

ASCII button code Up to 63 alphanumeric characters.

If you need to use the bracket delimiters in a stored ASCII command, you need to use
the insert brackets feature. With this feature, one character replaces the left bracket
( [ ) and another character replaces the right bracket ( ] ). The default values are a
single quote mark ( ‘ ) in place of the left bracket and a double quote ( “ ) in place of
the right bracket. The TPT150 replaces the characters with the bracket delimiters in
the stored ASCII or hex command string.

X8

=

Hex button code

Similar to the ASCII button code,

X7

, with the addition of an ASCII-to-hex conversion

before the value is stored. For example, if you send the ASCII value 0F, the TPT150
converts it to the hex value 0F. When you press the button, the TPT150 sends 0F hex.
Entries must be in pairs; use a leading 0 if necessary. Letters must be uppercase.
Spaces between bytes are not allowed.

The insert brackets feature is not available for hex codes.

X9

=

Projector power timeout interval

000 or 001 - 255 (minutes). 000 = no timeout.

X10

= Power on (warm up) delay (in seconds)

000 – 060

X11

= Power off (cool down) delay (in seconds)

000 – 256

Leading zeroes in the power on and power off delay are accepted but not required.

X12

= Baud rate

0 = 1200

1 = 2400

2 = 4800

3 = 9600 (default)

4 = 19,200

5 = 38,400

X13

= Parity mode: 0 = no parity (default), 1 = odd parity, 2 = even parity

X14

= Stop bits: 0 = 1 stop bit, 1 = 2 stop bits

X15

= Flow control mode: 0 = disable (default), 1 = enable (software flow control (Xon/Xoff)

X16

= Reset level: 0 = reset the serial port to 9600 baud, no parity, Xoff, and half duplex mode; reset the address

to 97; and enable the front panel. Do not reset input codes, projector power codes, or
volume settings.

1 = perform all of the same resets AND erase all input codes, projector power codes, and

volume settings.

X17

= Architectural information:

S150•{serial #(9 digits)}{Rev level (1 character)}{firmware #(5 or 6 digits)}{firmware Rev level(2 digits)}

{selected baud rates}1200,2400,4800,9600,19200,38400•{reserved for future use}