Cable management – CHIEF XPAU Series User Manual

Page 10

Advertising
background image

XPAU

Installation Instructions

10

Cable Management

NOTE:

The following cable management options may vary

based on type of display being mounted and user
preference.

1.

Use two 1/4-20 x 1/2” Phillips pan machine screws (L) to
attach two cable hooks (K) to bottom of column assembly
(F). (See Figure 12)

Figure 12

2.

Place FCA clip (U) into groove on back of Fusion mount with
clip handle in a vertical position. (See Figure 13)

3.

Rotate FCA clip (U) 90° in either direction until clip handle is
in a horizontal position. (See Figure 13)

4.

Repeat Steps 2-3 for all clips to be installed.

Figure 13

5.

Route cables along FCA clips to be used for cable
management. (See Figure 14)

6.

Use cable ties (V) to secure cables to FCA clips. (See
Figure 14)

Figure 14

7.

Route cables from display through inside of column
assembly attaching at cable management attachment
points and/or accessory bracket as desired. (See Figure 15)

IMPORTANT ! : Route cables when display is at its
highest point and make sure enough slack exists so that
height may be adjusted without straining the cables!

Figure 15

(K) x 2

(L) x 2

1

(F)

2

3

3

clip handle

(U)

5

6

(V)

7

7

7

7

clips

underneath