User manual – eLine Technology ECO3 User Manual User Manual

Page 56

Advertising
background image

56

User Manual

4.9.4 Restore Default

The way to restore default setting: After login, through “System Management”-> “Default” conti nuous operations to enter the interface, the

interface is as follows:

Note: Network IP and port, System time, user account and hard disk management wouldn’t be rest ore default when do this operation.System

default parameters:

Common Para.:Contrast(5:1),Video format (PAL);Record overwrite mode(Auto cycle);Disk error alert(Ena bled);Open auto locking(Enabled),auto

Disk format: System supports only FAT32 format, the capacity of the HDD is above 32G.System supports only one partition for backup.

Format: Select the HDD NO., then focus on the “format” icon and press “OK” to choose the type of the partition (DATA or BACKUP ). The

interface is as follows, after you confirmed the partition type, press “OK”, the system will prompt “It’s formatting...”.

lock time 3 minutes;Date format(YYYY-MM-DD);Display channel

name (Enabled);Display time(Enabled);Display temperature(Enabled);

Channel switch(Closed).

Rec. Para.:Record mode(All);Encoding stream type(VBR);Encoding

stream(512K);Record quality(High);Video frame(25);Audio(Enabled);

Transmission encoding stream(512K);Transmission record quality(High);

Transmission audio(enabled).

Record Mode:Manual(Closed);Schedule(Closed);Motion detection

(Closed);Alarm detection(Closed).

Network:Auto redial(Closed);Auto login(Closed).

COM:Baudrate(9600);Data bit(8);Parity bit(None);Stop bit(1);Keyboard

address(1);Protocol(Unknown).

Channel:Channel name(Reset to default);Video loss alarm(Enabled);

Advertising