A&D Super Wash Down Scales SW-150KL User Manual

Page 19

Advertising
background image

17



Three-level comparator mode

Results

Comparison formula

LED display

LO

Displayed value < LO limit value

(Or over in the negative value)

( Red LED on)

OK

LO limit value ≤ Displayed value ≤ HI limit value

( Green LED on))

HI

HI limit value < Displayed value

(Or over in the positive value)

( Red LED on)

LO limit value = Lower limit value
HI limit value = Upper limit value

‰

The comparator values are common to the weighing and counting mode.

‰

Ignore the decimal point when setting the comparator values.

For example, when the weighing capacity is 6 kg and the setting value is “001000”:

Display mode

Limit value

Capacity / Minimum display

Normal resolution kg

1.000 kg

6.000 kg / 0.002 kg

High resolution kg

1.000 kg

6.000 kg / 0.001 kg

Maximum resolution kg

0.1000 kg

6.0000 kg / 0.0005 kg

Normal resolution oz

100.0 oz

210.0 oz / 0.1 oz

High resolution oz

10.00 oz

210.00 oz / 0.05 oz

Maximum resolution oz

10.00 oz

210.00 oz / 0.02 oz

Counting mode

1000 pcs

‰

The comparator values are maintained even if the power is turned OFF.

‰

Judgment order of comparison is from the top row to the bottom in the comparator

mode tables

‰

In this mode, the entered comparator values are not judged. Even if the upper limit

value is less than the lower limit value, no error will be output.

















Advertising