13.2. OP-03 RS-232C / RELAY OUTPUT

This interface allows the SW scale to be connected to an AD-8121 printer or a
personal computer, and the relay outputs for comparator results are also available.
‰

When OP-03 is installed, the dust-tight and water-tight performance of the scale will

be degraded.

‰

OP-03 includes an interface board, two connector cables (7 and 10 pins), two cable

glands and two screws (M3x8).

13.2.1. Installing OP-03





























1.LOLO
2.LO
3.OK
4.HI
5.HIHI
6.COM
7.SHLD

1.RXD
2.TXD
3.DSR
4.SG
5.SHLD

6 mm

(AWG 26~16)

Terminal block

M4 screw (10 pcs)

Display rear cover

Cable glands

Interface board

M3x8 screws

Peel

Connector cable

To the

external device