11

Technical data

6.6. electrical data with as-interface bus

control (optional)

Connections

circular plug-in connector
(M12, 4 pole plug)

Supply voltage

29.5 V – 31.6 V DC
(according to specification)

Units without external supply voltage:

Max. power
consumption

150 mA

Units with external supply voltage:

External supply voltage 24 V ± 10 %, the supply voltage unit must

feature a secure disconnection in accor-
dance with IEC 364-4-41 (PELV or SELV)

Max. power
consumption

100 mA

Max. power
consumption
from AS interface

50 mA

6.7. pneumatic data

Control medium

Quality classes in accordance with DIN ISO
8573-1

Dust content

Class 5, max. particle size 40 µm, max. par-
ticle density 10 mg/m³

Water content

Class 3, max. pressure dew point - 20 °C or
min. 10 degrees below the lowest operating
temperature

Oil content

Class 5, max. 25 mg/m³

Temperature range
of compressed air

0 – +60 °C

Pressure range

1.4 – 7 bar

Air flow rate

95 l

N

/ min (at 1.4 bar

2)

) for aeration and

deaeration
150 l

N

/ min (at 6 bar

2)

) for aeration and

deaeration
(Q

Nn

= 100 l

N

/ min (according to definition for

pressure drop from 7 to 6 bar absolute).

Connections

Internal thread G1/4“

2)

Pressure specifications: Overpressure with respect to
atmospheric pressure

english

Type 8791