17

Installation

Guide piece

O-ring

Spindle extension

Puck holder

Switch spindle

Spindle (actuator)

Fig. 13: Installing the switch spindle 26xx and 27xx

Actuator size 125 and bigger:
remove existing spindle extension and replace with the new one.
To do this, apply some screw locking paint (Loctite 290) in the
tapped bore of the spindle extension.

Screw the guide piece into the cover of the actuator using a face
wrench

1)

(torque: 8.0 Nm).

To secure the switch spindle, apply some screw locking paint
(Loctite 290) to the thread of the switch spindle.

Screw the switch spindle onto the spindle extension. To do this,
there is a slot on the upper side (maximum torque: 1 Nm).

Push the puck holder onto the switch spindle until it engages.

1)

journal Ø: 3 mm; journal gap: 23.5 mm

2. install linear remote sensor

Push the Remote Sensor onto the actuator. The puck holder
must be aligned in such a way that it is inserted into the guide
rail of the Remote Sensor.

Guide rail

Puck holder

Fig. 14: Aligning the puck holder

Press the Remote Sensor all the way down as far as the actuator
and turn it into the required position.