Burkert Type 8798 User Manual

Page 18

Advertising
background image

18

Installation

Fastening

screws (2x)

max. 0.5 Nm

Fig. 15: Installing the linear Remote Sensor

note!

too high torque when screwing in the fastening screw does
not ensure protection class ip65 / ip67!
• The fastening screws may be tightened to a maximum torque of

0.5 Nm only.

Attach the Remote Sensor to the actuator using the two side fas-
tening screws. In doing so, tighten the fastening screws hand-tight
only (maximum torque: 0.5 Nm).

8.2.3. rotating the actuator module

The actuator module (Remote Sensor and actuator) can
be rotated for straight seat valves and angle seat valves
belonging to series 2300, 2301 and 27xx only!

The position of the connections can be aligned steplessly by rotating
the actuator module (Remote Sensor and actuator) through 360°.

Only the entire actuator module can be rotated. The Remote
Sensor cannot be rotated contrary to the actuator.
The process valve must be in the open position for
alignment of the actuator module!

Danger!

risk of injury from high pressure!
• Before dismounting pneumatic lines and valves, turn off the

pressure and vent the lines.

procedure:

Clamp valve housing in a holding device (only required if the
process valve has not yet been installed).

Control function A: Open process valve.

Using a suitable open-end wrench, counter the wrench flat on
the pipe.

English

Type 8798

Advertising