Technical data, Conditions of use, Conformity to standards and directives – Burkert Type 8012 User Manual

Page 14: General technical data, Mechanical data

Advertising
background image

14

Technicaldata

Type 8012

6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature

-15 to +60 °C

Air humidity

< 80%, non condensated

Protection rating

• IP67 (version with M12 fixed

connector), female connector wired,
plugged in and tightened

• IP65 (version with cable gland)

6.2.

conformity to standards and
directives

The device conforms to the EC directives through the following
standards:
• EMC : EN 61000-6-2, EN 61000-6-3
• Safety: EN 61 010-1
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure (S012 fitting of DN06 to DN65 in PP, PVC, PVDF, brass

or stainless steel): the device can only be used in the following
cases (depending on the max. pressure, the DN of the pipe and
the fluid)

type of fluid

conditions

Fluid group 1, par. 1.3.a

DN ≤ 25 only

type of fluid

conditions

Fluid group 2 par. 1.3.a

DN ≤ 32
or DN > 32 and PNxDN ≤ 1000

Fluid group 1 par. 1.3.b

PNxDN ≤ 2000

Fluid group 2 par. 1.3.b

DN ≤ 200

6.3.

General technical data

6.3.1. mechanical data

component

material

SE12 electronic housing

PPS

Cable gland, M12 fixed
connector

PA

Cable, 1 m

PVC, T

max

= 80 °C

Seal exposed to the fluid

FKM (EDPM on request)

Seal exposed to the ambient air

EDPM

Paddle-wheel holder

PVDF

Paddle-wheel

PVDF

Paddle-wheel axis and
bearings

ceramic

Body of the S012 fitting

stainless steel (316L/DIN1.4404),
brass, PVC, PP, PVDF

Screws

Stainless steel A4

English

Advertising
This manual is related to the following products: