If you encounter problems, Problems signalled by the leds – Burkert Type 8012 User Manual

Page 42

Advertising
background image

42

Maintenanceandtroubleshooting

Type 8012

10.4. if you encounter problems

danger

Risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and drain the

pipe before loosening the process connections.

Risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source before car-

rying out work on the system.

• Observe all applicable accident protection and safety regulati-

ons for electrical equipment.

Risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before loosening

the process connections.

Risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention and

safety relating to the use of aggressive fluids.

10.4.1. problems signalled by the leDs

status
red leD

status
green
leD

status
current
output

possible
cause

Recommended
action

Flashes
3 times
every
second

Off

22 mA

Full scale
exceeded (flow
rate in the pipe
is too high)

Check the process
parameters

On

Off

22 mA

Memory
problem

Switch the power
supply off then on.
If the error per-
sists, contact your
Bürkert retailer.

Off

Flashes
twice
every
second

22 mA

The device
with optical
detection is
mounted in the
wrong direction

Mount the device,
ensuring that the
arrow on the side
of the housing indi-
cates the direction
of the fluid.

English