Version with pulse output – Burkert Type 8012 User Manual

Page 9

Advertising
background image

9

Generalinformation

Type 8012

Depending on the version, the electrical connection is made using a
1 m long cable or a multi-pin M12 fixed connector which position can
be adjusted.
Depending on the version, the device is equipped:
• with one pulse output
• or one pulse output and one 4-20 mA current output.

Paddle-wheel

SE12

S012

Location of the LEDs
(depending on the version)

5.2.2. Version with pulse output

On the 16 basic versions of the SE12 module (see chap. 5.5), the
NPN pulse output generates a signal with a frequency f proportional
to the rotation frequency of the paddle-wheel.
To obtain a flow rate Q, this frequency must be divided by a propor-
tionality factor K according to the following formula:

Q = f/K

Table 1 : Characteristics of the pulse output

characteristic
of the pulse
output

possible configura-
tions (on request)

pulse output of
the basic versions

Transistor wiring

• NPN
• or PNP

NPN

Behaviour of the
output

• Frequency propor-

tional to the rotation of
the paddle-wheel (see
above)

• or frequency propor-

tional to a volume (see
chap. 9.2.1)

• or switching mode

(see chap. 9.2.2)

• or mode detecting the

immediate or delayed
change of circulation
direction of the fluid
(only on versions with
optical sensor) (see
chap. 9.2.3)

Frequency propor-
tional to the rotation
of the paddle-wheel

English