Maintenanceandtroubleshooting

Type 8012

Warning

Risk of injury due to non-conforming maintenance.
• Maintenance must only be carried out by qualified and skilled

staff with the appropriate tools.

• Ensure that the restart of the installation is controlled after any

interventions.

10.2. cleaning

Depending on the nature of the fluid, regularly check for clogging of
the paddle-wheel.

note

the device may be damaged by the cleaning liquid.
• Clean the device with a cloth slightly dampened with water or a

cleaning liquid compatible with the materials the device is made

of.

10.3. Replacing the seal

O-ring for metal fitting

O-ring for plastic fitting

Fig. 28 : Exploded view of the 8012

Unscrew the 4 screws in the electronic module and remove it
from the fitting.

Remove the used seal.

Clean the surfaces on which the seal is placed.

Insert the new seal (see Fig. 28).

Position the electronic module on the fitting so that the arrow
points in the fluid direction on versions with optical sensor.

Insert the 4 screws into the electronic module (use the long
screws for a plastic S012, DN6 or DN8 fitting).

Tighten the 4 screws in an alternating pattern, to a torque of
1.5 Nm.