Installationandwiring

Type 8012

Install the device on the pipe in such a way that the upstream
and downstream distances are respected according to the
design of the pipes, as per Fig. 4 and the EN ISO 5167-1
standard.

With regulating valve

Pipe with 2 elbows at 90°

in 3 dimensions

Pipe with 2 elbows

at 90°

Pipe with 1 elbow at 90°

or 1 T-piece

With pipe expansion

With pipe reduction

50 x DN

5 x DN

40 x DN

5 x DN

25 x DN

5 x DN

20 x DN

5 x DN

18 x DN

5 x DN

15 x DN

5 x DN

Fig. 4 : Upstream and downstream distances depending on the

design of the pipes.

If necessary, use a flow conditioner to improve measurement
precision.

Install the device in such a way that the paddle-wheel axis is
horizontal (Fig. 5).

Prevent the formation of air bubbles in the pipe in the section
around the device (Fig. 6).

Ensure that the pipe is always filled in the section around the
device (Fig. 7).

Correct

Incorrect

Fig. 5 : The paddle-wheel axis must be horizontal

English