6

TECHNICAL CHARACTERISTICS

ENVIRONMENTAL USE CONDITIONS

‰

The transmitter can be installed internally or externally

‰

Altitude: from –200m to 2000m (from -656 to 6560 feet)

‰

Humidity range: 0-85% without condensation

OPERATING TEMPERATURE

Consider the operating temperatures more restrictive between transmitter and sensor
* For discontinuous use, a thermostat heat source installation may be necessary.

Data plate

On the data plate there is some technical information:

MODEL: Transmitter Model

S/N: Serial Number of the transmitter

SUPPLY: Main power supply

Hz: Supply frequency (AC)

POWER: Maximum power consumption

IP: Protection grade

T: Operating temperature

COUPLING: Serial number of sensor coupled

ITEM: free for user

Min. *

Max

°C

-10

50

°F

14

122

ELECTRIC CHARACTERISTICS

Transmitter classification: class I, IP65, installation category (overvoltage) II, rated
pollution degree 2.

Power supply

versions

Power supply

voltage

Power supply

frequency

Max

power

HV

100-240V~

44-66Hz

6W

LV

18-45V

//

18-45V~

44-66Hz

‰

Voltage changes must not exceed ±10% of the nominal one.

‰

Input/output insulated up to 500V.

‰

The output 4-20mA (optional) is electrically connected to the ON/OFF outputs and
the output power supply (24V

).

Advertising