5

Setup - Sensors up to software 3.99

5

.1 Common adjustment menu for all signal

outputs

Through the parameter adjustment the instrument is adapted to the
application conditions. The parameter adjustment is carried out via an
adjustment menu.

Information:
In this operating instructions, all general parameters are described.
Additional instrument-specific parameters are described in the
operating instructions of the respective sensor.

The following presentations are available in the measured value
display:

l

Level as digital value, sensor TAG

l

Level as digital value and bar graph, sensor TAG

l

Only with pressure transmitters: Level or pressure as digital value,
temperature value

With [->] you select different presentations of the measured value.
From each of these presentations, you can reach with [OK] the menu
overview. With [ESC] you move from the menu overview again to the
measured value indication.

The main menu is divided into five sections with the following
functions:

Basic adjustment

Display
Diagnostics
Service
Info

To damp process-dependent measured value fluctuations, you have to
set an integration time of 0 … 999 s in this menu item.

Depending on the sensor type, the factory setting is 0 s or 1 s.

Damping

0

s

In this menu item you select the linearization curve:

l

Linear

l

Horizontal cylindrical tank

l

Spherical tank

l

User programmable

Measured value indica-
tion

Main menu

Basic adjustment/Damp-
ing

Basic adjustment/Linea-
rization curve

Indicating and adjustment module

11

5

Setup - Sensors up to software 3.99

41787

-

EN

-

120316