Panels

V-Series Panels

Each V-Series panel (V12LD, V12PD, V24LD, V24PD, V12LDD,
V12PDD, V12LDE, V12PDE) has an external power supply. AC
voltage for these panels can be 100 to 240 VAC without any switching
or fuse changes.

4000 Series II Panels

Each 4000 Series II panel (4212, 4215, 4222, 4224, 4226, 4294, 4203,
4206, 4230, 4230V) has an external power supply. AC voltage for
these panels can be 100 to 240 VAC without any switching or fuse
changes.

ICS Panels and i-Stations

Each ICS-2003 and ICS-1016 panel has an external power supply. A
bracket has been provided to mount this external supply if necessary.
AC voltage for these panels can be 90 to 260 VAC without any
switching or fuse changes.

The ICS-102/92/62/52 panels have wall-mounted transformers for 110
VAC and in-line transformers for 220 VAC. Confirm that the correct
ones have been supplied for the installation.

The i-Stations have internal power supplies, with removable AC power
cords. The power supplies are “universal,” operating over a voltage
range of 90 to 245 VAC and 50 to 60 Hz. The maximum dissipation is
40 W.

Each panel will need to be plugged into an AC source at its location.

8. Configure the System

The Eclipse Configuration System (ECS) programming software allows
the system to be configured for the operating environment. With this
software a system administrator can assign port or panel names,
declare interface port functions, assign “labels” to keys on panels, and
perform many other functions. Refer to the Eclipse Configuration
System Manual for instructions on using the software.

9. Verify the Operation of the System

Once the system is configured, a detailed check of each panel,
interface connection, control function, and other features should be
performed. Each audio path, relay output, and control input needs to
be exercised to verify proper operation. Each software function, such
as Party Lines, ISO, and IFB must be verified. Each installation is
different, so it is beyond the scope of this manual to outline in detail
this phase.