Eclipse median matrix, Eclipse pico matrix, Eclipse-32 matrix – Clear-Com Eclipse-Omega User Manual

Page 26: Eclipse median matrix -2, Eclipse pico matrix -2, Eclipse-32 matrix -2

Advertising
background image

Clear-Com Communication Systems

Eclipse Matrix Installation Instruction Manual

3 - 2

Clear-Com ships each matrix with two power supplies already
installed. When the matrix is received, connect each of the power
supplies to a dedicated branch of AC mains power using the IEC
power connectors on the Eclipse Omega frame’s rear panel.

A fully equipped Eclipse Omega frame requires 100 to 240 VAC at 50
to 60 Hz with a maximum dissipation of 300 W.

Eclipse Median Matrix

The Eclipse Median matrix has two internal, Euro Cassette, plug-in
power supplies. Each of the power supplies must be connected to a
dedicated branch of AC mains power. The matrix will continue to
operate even if one of the AC power branches fails.

Clear-Com ships each matrix with two power supplies already
installed. When the matrix is received, connect each of the power
supplies to a dedicated branch of AC mains power using the IEC
power connectors on the Eclipse Median frame’s rear panel.

A fully equipped Eclipse Median frame requires 100 to 240 VAC at 50
to 60 Hz with a maximum dissipation of 300 W.

Eclipse Pico Matrix

The Eclipse Pico matrix has two internal power supply units. One
power supply unit can power an entire matrix; the second unit provides
a backup in case of an equipment failure.

In addition, the two supplies have separate IEC connectors to AC
mains power, and are designed for completely automatic and
transparent changeover between supplies in the event of an outage on
one of the AC mains circuits.

The power supplies are “universal”, operating over a voltage range of
100 to 240 VAC at 50 to 60 Hz.

An Eclipse Pico matrix requires 100 to 240 VAC at 50 to 60 Hz with a
maximum dissipation of 40 W.

Eclipse-32 Matrix

The Eclipse-32 matrix has two internal power supply units. One power
supply unit can power an entire matrix; the second unit provides a
backup in case of an equipment failure.

In addition, the two supplies have separate IEC connectors to AC
mains power, and are designed for completely automatic and
transparent changeover between supplies in the event of an outage on
one of the AC mains circuits.

The power supplies are “universal,” operating over a voltage range of
100 to 240 VAC at 50 to 60 Hz