SINGLE-PAIR DIGITAL

Single-pair digital wiring is accomplished with double-shielded 24 AWG
conductor CAT-6E enhanced STP cable. Pair 1 transmits and receives
multiplexed digital and analog between the matrix and the panel.

Note: Ensure that the “select” switch on the panel’s rear cover is

in the correct position for the intended use.

Figure 4-5: Wiring Matrix to Digital Panel Using RJ-45

WIRING THE MATRIX GENERAL-PURPOSE
OUTPUTS

A general purpose output or “relay” is a switch that is controlled
remotely. The relay is programmed in ECS to close a contact
whenever an intercom panel’s key is pressed. When the contact is
closed, it completes an electronic circuit’s signal path so that a remote
device, such as a light, is powered.

A GPO can be programmed to mute a speaker, to turn on an applause
light, to turn on a door lock, or to perform a variety of other functions.
For example, in order to get the attention of a panel operator working
in a high-noise environment, such as a control booth, a relay can be
programmed to switch on a light at that panel each time the panel
receives an incoming call, to ensure that the panel operator will not
miss the call.

The male 25-pin D-type socket labeled “GP OUT” on the rear of the
Eclipse matrix connects to eight general-purpose outputs (GPOs). The
general purpose outputs are single-pole double-throw relays with
contact ratings of 30 VDC (volts direct current) at 1 ampere. Shielded
cable should be used to connect GPOs.

Pair 2

Pair 1

Pair 3

Pair 4

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

Matrix Frame End

ATT-T568B (Modular Jumpers

Wired One to One)

Panel End

No Connection (NC)

No Connection (NC)

No Connection (NC)

Multiplexed Data/Audio

Multiplexed Data/Audio

No Connection (NC)

No Connection (NC)

No Connection (NC)