Clear-Com Communication Systems
Eclipse Matrix Installation Instruction Manual

3 - 5

INTERFACE MODULE FRAME POWER SUP-
PLY REQUIREMENTS

IMF-3 Interface Module Frame

As a rule-of-thumb, one PSU-101 power supply unit is required for
every two IMF-3 frames. There are two exceptions to this rule. The first
exception occurs when the frames have a large number of CCI-22
party-line interfaces which require no DC power from the IMF-3 frame.
However, an IMF-3 with only CCI-22 interfaces still needs to be
connected to a PSU-101 as the IMF frame itself needs some DC
power for the circuitry on its rear panel.

The second exception occurs when using multiple TEL-14 telephone
interfaces. An IMF-3 interface frame will only power eight TEL-14
interfaces. If more TEL-14 interfaces are required, they must be
installed in a second IMF-3 frame with a second power supply.

A PSU-101 requires 90 to 260 VAC at 45 to 65 Hz with a maximum
dissipation of 80 W. A PSU-101 connected for redundancy requires
very little AC current unless it is used.

An audible alarm is included in the PSU-101, and an additional set of
alarm-relay contacts are provided on the supply. Clear-Com
recommends that these contacts be connected to the external alarm
input of the matrix frames. If any of the power supplies in the PSU-101
fails, it would cause a system alarm. LEDs on the front of the
PSU-101s will indicate the failure.

Installing two PSU-101 power supplies per application provides
redundancy because either of the two PSU-101 power supplies can
power a complete system. If one fails, it can be removed without
interruption of the entire system. Rear panel connectors provide easy
parallel connection to the IMF-3 Interface Module Frame.

The current capacities of the power supplies are as follows:

• +9 V analog 3.0 A

• -9 V analog 3.0 A

The following chart provides the current drain of the +/- analog power
supplies for all components in the system. Some devices, such as
interfaces, have a varying current depending on the operation of
features. In applications where it is possible to activate all operating
features of all components used, use the maximum current column for
planning.