Chapter 5: Programming commands

116

A776 (B780) Programming Guide

A776-PG00001 C 12/09

Examples of variable length field format specifications

Account #, all characters in the field, keep spaces and dashes

A

Account #, all characters in the field, replace spaces and dashes

xA

Account #, maximum 12 characters, keep spaces and dashes

12A

Account #, always 12 characters zero filled, remove spaces and dashes 012XA

Other parameters

Error number

E

One digit returned

0

Read OK

1

Read error: bad character, empty

field invalid length,

check digit invalid

Status

S

Two digits returned

01

No MICR data

09

Mexican check

08

Canadian check

05

Error in transit number

07

Error in account number

04

Error in check serial number

10

Business or commercial check

11

Amount field present

00

No error

Field separator

‘x

Field separator preceded by a single quote, so a field separator of the letter A would be

sent as ‘A (0x27 0x41).

If a carriage return is specified as a separator (0x27 0x0D), a final carriage return must still

terminate the parsing parameter string.

Country code

Un

One digit returned

n

Returned if US check

nothing

Returned if not US check

Country code

Km

One digit returned

m

Returned if Canadian check

nothing

Returned if not Canadian check

Check type

L

One digit returned

1

Personal check

2

Business or commercial check

Advertising