Chapter 5: Programming commands

59

A776-PG00001 C 12/09

A776 (B780) Programming Guide

Exceptions

The settings do not apply in page mode, However they can be set or cleared in page mode.

Double-strike printing cannot be used with bit-images or downloaded bit-images.

This command functions the same as A756 when the printer is in A756 emulation mode. In A776 native mode, the
command takes a parameter to enable and disable it.

Related information

Printer output is the same as in emphasized mode.

Cancel double-strike

ASCII

ESC H

Hexadecimal 1B 48

Decimal

27 72

Turn off double-strike mode on the slip station in A756 emulation mode.

Select or cancel italic print

ASCII

ESC I n

Hexadecimal 1B 49 n

Decimal

27 73 n

Value of n:

0 = Off

1 = On

(When 0 and 1 are the least

significant bit, LSB)

Default:

0 (Off)

Turns italic print mode on or off.
Italic print mode is available for built-in, user-defined characters. This command only works on the receipt station.

Select international character set

ASCII

ESC R n

or

ESC t n

Hexadecimal 1B 52 n

or

1B 74 n

Decimal

27 82 n

or

27 116 n

Value of n:

A776 native mode

A756 emulation

0 = Code Page 437

0 = Code Page 437

1 = Code Page 850

Not 0 = Code Page 850

2 = Code Page 852

3 = Code Page 860

4 = Code Page 863

5 = Code Page 865

6 = Code Page 858

7 = Code Page 866

8 = Code Page 1252

9 = Code Page 862

10 = Code Page 737

12 = Code Page 857

Continued . . .