CognitiveTPG B780 User Manual

Page 93

Advertising
background image

Chapter 5: Programming commands

81

A776-PG00001 C 12/09

A776 (B780) Programming Guide

Related information

This command is utilized in the CognitiveTPG LogoEZ

®

utility. The utility can be used to pre-configure new printers with

a default colorization set-up without requiring any application changes. The default set-up was designed to provide a
general level of colorization features that would not affect the printer operation. You can expand beyond the default
features of the utility by modifying the application at the host. However, do not attempt to modify the settings within
the utility.

f = 1: s = 1H

a = 30H

f = 2: s = 32H

r = 19H

f = 3: s = 1H

r = 7H

t = 1H

f = 4: s = 30H

a = A0H

Convert 6-dots/mm bitmap to 8-dots/mm bitmap

ASCII

US EOT n

Hexadecimal 1F 04 n

Decimal

31 04 n

Value:

0 = Off

1 = On

(When 0 and 1 are the LSB)

Default:

0 (Off)

Selects or cancels 6-dot/mm to 8-dot/mm graphic emulation.

When the 6-dot/mm emulation is selected, logos and graphics are expanded horizontally and vertically during
download to emulate their size on a 6-dot/mm printer. The horizontal positioning commands also emulate positioning
on a 6-dot/mm printer.

Enable constant speed logos

ASCII

US { n

Hexadecimal 1F 7B n

Decimal

31 123 n

Value:

0 = disabled

1 = enabled

This command allows the firmware to determine the optimal speed to print a logo. It is set prior to downloading the
logo and reset after the logo has been downloaded.

In general, the “Set max target speed (1D A0 nl nh)” is the preferred command.

Advertising