Keypad lockout, Spare, Block select a – CONTREX CX-1200 User Manual

Page 20

Advertising
background image

Page 18

Figure 21 Keypad Lockout


ENABLE

8

9

J6

Com

DI_6


LOCKOUT

Figure 22 Spare


Spare

8

10

J6

Com

DI_7

Figure 23 Block Select A


Block Select A

1

3

J7

DI-8

Com

Keypad Lockout

(J6 pins 9, 8)
Digital Input 6

When the Keypad Lockout input is closed, the Control
Parameters that you have selected to "lock out" are
inaccessible from the front keypad. All of the Monitor
Parameters remain enabled.

Spare

(J6 pins 10, 8)
Digital Input 7

The Spare input is not defined at this time.

Block Select A

(J7 pins 1,3)
Digital Input 8

Block Select A is a maintained input. Close this input to
select "Block 1" as the active parameter block. When this
input is open, "Block 0" is the active block.

Advertising