CONTREX CX-1200 User Manual

Page 52

Advertising
background image

Page 50

Jog Reverse has sixth (the least) operating priority. Use Jog Reverse to “Jog” the drive Forward at the rate
indicated in Jog SP (CP-240). The acceleration and deceleration ramps are dictated by Acl Tm Jog (CP-241),
Dcl Tm Jog (CP-243) and Jog SP (CP-240). After the Jog Reverse input is deactivated and the ramped
reference has reached “0”, the CX-1200 automatically reverts to the R-Stop operating state.

To activate Jog Reverse:

Activate Low (closed to common), Level Sensitive, Not-Latched
Use momentary contact - needs to be maintained to remain active

Jog Forward

Jog Reverse

Common

F-Stop

R-Stop

H-Stop

Run

Common

Jog Fwd

Close Maintained

6

7

8

1

2

4

5

3

J6

H-Stop

Run

R-Stop

Jog Rvs

F-Stop

Figure 2-51 Jog Reverse Input

Advertising