Page 20

Figure 28 Sync Disable


Sync Disable

8

7

J7

Com

DI_13

Figure 27 Position Reset

Position Reset

6

8

J7

DI_12

Com

Figure 29 Phase Advance

Phase Advance

8

9

J7

Com

DI-14

Sync Disable

(J7 pins 7, 8)
Digital Input 13

Sync Disable is a maintained input. When it is closed, it
disables sync corrections.

Position Reset

(J7 pins 6, 8)
Digital Input 12

Position Reset is a momentary input. When it is closed, the
CX-1200 resets the Lead and Follower position information to
zero.

Phase Advance

(J7 pins 9, 8)
Digital Input 14

Phase Advance is a maintained input. When it is closed it
increments the CP selected by "Remote Scroll" (CP-400) at the
rate set by "Rmt Scroll Rate" (CP-401). As a maintained input,
Phase Advance is only active when the operator device is
closed.