Inputs – CONTREX CX-1200 User Manual

Page 40

Advertising
background image

Page 38

INPUTS

NOTE: Refer to pages 2-9 and 2-36 before you begin wiring.

Figure 2-39 Analog Input 2: Voltage Input

Figure 2-38 Analog Input 1: Voltage Input

5

6

7

8

JA

±12V Input

-

Common

+

+

-

2

3

4

8

JA

±12V Input

-

Common

+

+

-

Analog Input 1:

Voltage Input Wiring
(JA, Pins 2, 4, 8)

The Analog Input 1 can be used with either ±12 VDC or
0-20 mA inputs. Figure 2-38 displays the ±12 VDC
option.

For the differential inputs:

Connect JA pin 2 to the positive differential signal

source.

Connect JA pin 4 to the negative differential signal

source.

Connect JA pin 8 to the common of the differential

signal source.

For the non-differential inputs:

Connect JA pin 2 to the signal voltage source.
Connect JA pin 4 and JA pin 8 to the common of the

signal source.

Analog Input 2:

Voltage Input Wiring
(JA, Pins 5, 7, 8)

The Analog Input 2 can be used with either ±12 VDC or
0-20 mA inputs. Figure 2-39 displays the ±12 VDC
option.

For the differential inputs:

Connect JA pin 5 to the positive differential signal

source.

Connect JA pin 7 to the negative differential signal

source.

Connect JA pin 8 to the common of the differential

signal source.

For the non-differential inputs:

Connect JA pin 5 to the signal voltage source.
Connect JA pin 7 and JA pin 8 to the common of the

signal source